ISSN: 2167-7689
Pharmaceutical Regulatory Affairs: Open Access
Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Electrochemical Detection versus Ultraviolet Detection

Hideharu Shintani*

Chuo University, School of Science, 1-13-27, Kasuga, Bunkyo, Tokyo 112-8551, Japan

*Corresponding Author:
Hideharu Shintani
Faculty of Science and Engineering
Chuo University, 1-13-27, Kasuga
Bunkyo, 112-8551, Tokyo, Japan
Tel: +81425922336
Fax: +81425922336

Received date: April 08, 2014; Accepted date: April 09, 2014; Published date: April 28, 2014

Citation: Shintani H (2014) Electrochemical Detection versus Ultraviolet Detection. Pharmaceut Reg Affairs 3:e130. doi:10.4172/2167-7689.1000e130

Copyright: © 2014 Shintani H. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Pharmaceutical Regulatory Affairs: Open Access

Electrochemical detection (ED) is used for the sensitive detection and measurement of electro-active analytes in many areas of analytical chemistry and biochemistry. These applications range from electrode sensor devices via flow injection analyses to direct measurements of neurochemicals in brain tissue using in vivo cyclic voltammetry. In separation science, ED is used to detect and measure responsive analytes in flowing streams following analysis by high-performance liquid chromatography (HPLC) or capillary electrophoresis (CE). The use of ED with HPLC is by far and away the most important application of ED in flowing systems. The use of HPLC-ED grew by 5 times between the 1980s and the 1990s. However, its popularity should be compared to HPLC with fluorescence detection and HPLC with MS detection. Most Published date: HPLC methods use UV/VIS detection without fail.

Unlike UV or fluorescence detectors, ED does not exploit a physical property of an analyte, but an induced chemical change that results from an electrochemical reaction. ED must, therefore, be considered to be a type of post-column chemical reaction detector. ED differs, however, from other post-column reactors used in HPLC in that no reagents or reaction devices are normally required to effect the chemical change in the analyte. In addition, the reaction kinetics are usually fast leading to minimal extra-column effects. With UV detectors, selectivity is adjusted by varying the detection wavelength, lower wavelengths often giving enhanced sensitivity and a response from a wider range of analytes. A modest degree of selectivity is achieved by using UV detection in the aromatic region (240-270 nm) and traditionally 254 nm has proved popular. However, at lower wavelengths (200-210 nm), the absorption of the eluent, of other eluent constituents or of oxygen become limiting. Relatively few compounds show useful absorption at wavelengths higher than 340 nm (the lower limit of the deuterium lamp emission). Generally, responses are usually independent of eluent conditions. In ED detection both sensitivity and selectivity are adjusted by varying the potential maintained between the working and reference electrodes, higher potentials, up to a local maximum, giving increased sensitivity. However, higher potentials usually induce a response from more compounds and therefore compromise selectivity. In oxidative mode, oxidation of eluent constituents becomes limiting at higher applied potentials, whilst in reductive mode, interference from dissolved oxygen can prove difficult to exclude. The response at the electrode is also very dependent on the eluent composition, especially its pH. Thus, as in all analytical methods, it is the signal-to-noise (S/N) ratio that is important and the detection conditions eventually adopted for a separation are a compromise between the electrochemical response of the analyte, the optimum eluent for both detection and elution, and interference from the sample matrix or from noise or drift from electronic or other sources.

In HPLC-ED the column elute flows over the surface of an ‘inert’ electrode maintained at an appropriate positive or negative potential relative to a reference electrode. At the electrode surface analytes possessing electro active functional groups undergo oxidation or reduction. The electrons released travel via the electrode and the change in current can be measured and related to the concentration of the analyte. Modem electronics allow the applied (working) potential to be held within very tight limits while at the same time measuring and amplifying the very small currents created. Hence ED can be very sensitive. Both ED and fluorescence detectors can be at least 100 times more sensitive towards responsive compounds than a standard UV detector and are much more selective. Unfortunately, with time electrochemical reaction products tend to accumulate at the electrode surface leading to loss of activity and hence loss of detector response - this is the major reason ED remains a relatively specialized field compared with UV detection, which is much popular even though less sensitive and selective due to an easy handling.

The readers can choose which detectors may be the most appropriate detector for your purpose from the characteristics of the compound(s) of interest to determine in your study.

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Relevant Topics

Article Usage

  • Total views: 11303
  • [From(publication date):
    October-2014 - Oct 26, 2016]
  • Breakdown by view type
  • HTML page views : 7564
  • PDF downloads :3739

Post your comment

captcha   Reload  Can't read the image? click here to refresh

OMICS International Journals
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
OMICS International Conferences 2016-17
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

1-702-714-7001Extn: 9037

Business & Management Journals


1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

1-702-714-7001 Extn: 9042

© 2008-2016 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version