alexa Electrochemical Detection and Removal of Mercury (II) at DNA Modified Carbon Paste Electrode | Open Access Journals
ISSN: 2329-6577
Biological Systems: Open Access
Make the best use of Scientific Research and information from our 700+ peer reviewed, Open Access Journals that operates with the help of 50,000+ Editorial Board Members and esteemed reviewers and 1000+ Scientific associations in Medical, Clinical, Pharmaceutical, Engineering, Technology and Management Fields.
Meet Inspiring Speakers and Experts at our 3000+ Global Conferenceseries Events with over 600+ Conferences, 1200+ Symposiums and 1200+ Workshops on
Medical, Pharma, Engineering, Science, Technology and Business

Electrochemical Detection and Removal of Mercury (II) at DNA Modified Carbon Paste Electrode

MA Smaini, R Maallah, S Touzara, C Laghlimi, S El Qouatli and A Chtaini*

Molecular Electrochemistry and Inorganic Materials Team, Beni Mellal Faculty of Science and Technology, Sultan Moulay Slimane University, Marocco, USA

Corresponding Author:
Chtaini A
Molecular Electrochemistry and Inorganic Materials Team
Beni Mellal Faculty of Science and Technology
Sultan Moulay Slimane University, Maro, USA
Tel: 0021265129257
E-mail: a.chtaini@usms.ma

Received date: January 04, 2017; Accepted date: January 24, 2017; Published date: February 01, 2017

Citation: Smaini MA, Maallah R, Touzara S, Laghlimi C, El Qouatli S, et al. (2017) Electrochemical Detection and Removal of Mercury (II) at DNA Modified Carbon Paste Electrode. Biol Syst Open Access 6:173. doi:10.4172/2329-6577.1000173

Copyright: © 2017 Smaini MA, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution and reproduction in any medium, provided the original author and source are credited.

Visit for more related articles at Biological Systems: Open Access

Abstract

Herein, we report a simple and inexpensive way for the fabrication of a microelectrode, DNA modified carbon paste electrode (DNA-CPE). DNA is deposited onto carbon paste electrode surface by self-assembled monolayers. The electrochemical behaviour of DNA-CPE’s was studied by cyclic voltammetry (SWV) tests. The recorded CV’s showed two redox peacks simultaneously at E oxidation=0.3 V and E reduction=0.2 V. The recorded SWV curves at DNA-CPE have shown great efficiency in the analysis of mercury (II) at different concentrations.

Keywords

DNA; Modified electrodes; Mercury; SWV; Cyclic voltammetry

Introduction

Mercury is the only metal that can be found in the liquid state at room temperature; it enters the environment through not only coal burning but also through mining or industrial wastes. Mercury has the power to form amalgams with several metals, such as silver, it has been widely used in dentistry, but the new legislation prohibited its use because of its toxic effects [1,2]. The most commonly used methods are atomic absorption [3], inductively coupled plasma mass spectrometry [4] and cold vapor atomic fluorescence spectrometry [5]. The electrochemical methods have proved highly effective in detecting mercury, with many advantages, such as, simplicity of implementation and inexpensive. The use of mixed assembled mono layers of DNA has received an increasing attention for the determination of metal ions [6]. In this study, we have prepared a carbon paste electrode on which we have deposited by self-assembly a DNA film. This prepared electrode was used, in conjunction with electrochemical methods, as CV’s and SWV, for the removal and the detection of mercury (II). The DNA-CPE is successively exploited the favorable mechanical and electrochemical properties of carbon paste electrode, and the high flexibility of DNA structure to chelate mercury.

Experimental

Reagents and chemicals

All the chemicals used in this work, are of high quality. The carbon graphite was purchased from Aldrich, and was used in its state without modification. HgCl2 was obtained from Merck chemicals. Deionised water was used to prepare all solution. The DNA used in this work is taken from quail blood, according to the protocol below:

• 5 l of blood taken from the axillary vein is poured into an Eppendorf containing 500 μl of danazol,

• The solution is stirred for 5 min by vortexing and centrifuged at 6000 rpm/5 min,

• The supernatant is removed and then 400 μl of isopropanol is added to the residue remaining in the Eppendorf,

• The mixture was vortexed and centrifuged at 6000 rpm/5 min,

• The supernatant was removed and 500 μl of pure water was added to suspend the DNA.

Apparatus

The electrochemical studies were performed with a potentiostat (model PGSTAT 100, Eco Chemie B.V., Utrecht, The Netherlands) driven by a general purpose electrochemical systems data processing software (voltalab master 4 software). The three electrode system consisted of a modified paste electrode as the working electrode, a saturated calomel electrode (SCE) serving as reference electrode, and platinum as an auxiliary electrode.

Electrode preparation

The DNA-modified carbon paste electrode was prepared by thoroughly hand-mixing of high purity graphite powder (CP), then a portion of the resulting paste was grounded and squeezed into a homemade PTFE cylindrical tube (geometric area 0.1256 cm2) electrode. Inside the tube, the mass was in contact with a bar of carbon, which was in turn connected to an electric wire to complete the measurement circuit. DNA-CPE’s were prepared by immobilizing the DNA system by soaking the preformed carbon paste electrode in a solution containing the DNA solution.

Results and Discussion

A carbon paste electrode modified with DNA was carefully washed with distilled water, heated at room temperature and transferred to electrochemical cell containing 0.1 M NaCl electrolyte. Mercury was accumulated at DNE-CPE for 15 min [6]. CV scanning was performed from -2 to 2 V at a scan rate of 100 mV/s.

Figure 1 show the voltammograms recorded, respectively at CPE and DNA-CPE, in 0.1 M NaCl. Two reduction peaks were observed at DNA-CPE towards the negative sweep direction, the first one around -0.12 V and the second approximately 0.1 V versus SCE; these peaks can correspond to internal reductions of the macro-DNA molecule.

biological-systems-electrolytic-solution

Figure 1: CV’s recorded, in electrolytic solution, at CPE (curve a) and DNA-CPE (curve b), scan rate 100 mV/s.

Electrochemical impedance spectroscopy (EIS) corresponding to CPE and DNA-CPE can be seen in Figure 2. We can notice that the two electrodes exhibit a large ohmic drop, i.e., a high electrolyte resistance, which masks the part of the high-frequency diagram. However, we can see a drop in total impedance at low frequencies in the case of DNA-CPE; this is probably due to the appearance of an additional capacitance relative to the DNA film.

biological-systems-DNA-CPE

Figure 2: EIS spectra of CPE (curve a) and DNA-CPE (curve b), the frequency range was set on 1 Hz up to 1 MHz.

Mercury (II) was pre-concentrated from the solution into the DNAmodified CPE at open circuit potential, then the CV’s was used to reduce Hg2+ (Figure 3-P1), According to the following reaction:

biological-systems-Cyclic-voltammograms

Figure 3: Cyclic voltammograms of different concentrations of Hg(II) at DNA-CPE in 0.1 M NaCl, scan rate 100 mV/s.

equation

The peak P2 corresponds to the phenomenon of oxidation of Hg and of salting out of Hg2+, by following the mechanism below:

equation

Figure 4 shows some of typical square-wave voltammetry (SWV) curves recorded at DNA-CPE after being in contact with different mercury (II) concentrations for 15 min of accumulation time, then, we established a calibration curve based on the current density of the observed peak. As can be seen, the current density of the peak depends linearly on the mercury concentration. The resulting equation of the linear regression analysis is as follows (Figure 5).

biological-systems-voltammograms

Figure 4: Square wave voltammograms in 0.1 M NaCl, preconcentration time 15 min of mercury (II) at different concentrations.

biological-systems-Calibration-curves

Figure 5: Calibration curves of Hg2+ in 0.1 M NaCl.

iP1=-0.029 × [Hg2+]-0.373 R2=0.966

and

iP2=0.019 × [Hg2+]+0.268 R2=0.991

The effect of the scanning rate has been studied, and we find that the anodic and cathode peak current increase linearly for scanning rate value variant between 40 and 140 mV/s (Figures 6 and 7), suggesting that the electrons transfers for mercury at the DNA-CPE is adsorption controlled reaction [7].

biological-systems-mercury-solution

Figure 6: Cv’s recorded at DNA-CPE preconcentrated in mercury solution, in 0.1 M NaCl, Effect of the scan rate.

biological-systems-current-densities

Figure 7: Dependence of the current densities of the peaks (P1 and P2) with the scanning rate.

The morphology of the prepared electrode surfaces, CPE (a), DNACPE (b) and DNA-CPE after accumulating in mercury solution (c), was studied by optical microscopy, (Figure 8). We can see that the DNA film forms a thin layer that covers the all carbon surfaces. Mercury adsorbed into DNA film forms a porous structure [8].

biological-systems-optical-microscopy

Figure 8: Images taken by optical microscopy for: a- CPE, b- DNACPE and DNA-CPE after preconcentration in Hg2+ solution.

Conclusion

This work demonstrated that DNA-CPE is a feasible alternative for the analytical determination of mercury (II). Analytical results show that the proposed electrode was able to detect very low concentrations with good sensitivity and reproducibility.

References

Select your language of interest to view the total content in your interested language
Post your comment

Share This Article

Relevant Topics

Recommended Conferences

Article Usage

  • Total views: 244
  • [From(publication date):
    April-2017 - Aug 16, 2017]
  • Breakdown by view type
  • HTML page views : 210
  • PDF downloads :34
 
 

Post your comment

captcha   Reload  Can't read the image? click here to refresh

Peer Reviewed Journals
 
Make the best use of Scientific Research and information from our 700 + peer reviewed, Open Access Journals
International Conferences 2017-18
 
Meet Inspiring Speakers and Experts at our 3000+ Global Annual Meetings

Contact Us

Agri, Food, Aqua and Veterinary Science Journals

Dr. Krish

agrifoodaquavet@omicsonline.com

1-702-714-7001 Extn: 9040

Clinical and Biochemistry Journals

Datta A

clinical_biochem@omicsonline.com

1-702-714-7001Extn: 9037

Business & Management Journals

Ronald

business@omicsonline.com

1-702-714-7001Extn: 9042

Chemical Engineering and Chemistry Journals

Gabriel Shaw

chemicaleng_chemistry@omicsonline.com

1-702-714-7001 Extn: 9040

Earth & Environmental Sciences

Katie Wilson

environmentalsci@omicsonline.com

1-702-714-7001Extn: 9042

Engineering Journals

James Franklin

engineering@omicsonline.com

1-702-714-7001Extn: 9042

General Science and Health care Journals

Andrea Jason

generalsci_healthcare@omicsonline.com

1-702-714-7001Extn: 9043

Genetics and Molecular Biology Journals

Anna Melissa

genetics_molbio@omicsonline.com

1-702-714-7001 Extn: 9006

Immunology & Microbiology Journals

David Gorantl

immuno_microbio@omicsonline.com

1-702-714-7001Extn: 9014

Informatics Journals

Stephanie Skinner

omics@omicsonline.com

1-702-714-7001Extn: 9039

Material Sciences Journals

Rachle Green

materialsci@omicsonline.com

1-702-714-7001Extn: 9039

Mathematics and Physics Journals

Jim Willison

mathematics_physics@omicsonline.com

1-702-714-7001 Extn: 9042

Medical Journals

Nimmi Anna

medical@omicsonline.com

1-702-714-7001 Extn: 9038

Neuroscience & Psychology Journals

Nathan T

neuro_psychology@omicsonline.com

1-702-714-7001Extn: 9041

Pharmaceutical Sciences Journals

John Behannon

pharma@omicsonline.com

1-702-714-7001Extn: 9007

Social & Political Science Journals

Steve Harry

social_politicalsci@omicsonline.com

1-702-714-7001 Extn: 9042

 
© 2008-2017 OMICS International - Open Access Publisher. Best viewed in Mozilla Firefox | Google Chrome | Above IE 7.0 version